LEMENG

10/20/2026

Using Hydrophilic Fumed Silica 200 for Rheology and Powder Flow

Using Hydrophilic Fumed Silica 200 for Rheology and Powder Flow

Introduction

Hydrophilic Fumed Silica 200 can adjust rheology, settling, anti-sag behavior or powder flow. Performance depends on surface area and chemistry, base formulation, mixing sequence and shear. This guide covers trial design and handling. Evonik and WACKER values below refer only to their own products, not Lemeng’s grade.

1. Why a hydrophilic fumed silica can change flow

Fumed silica forms branched aggregates and larger agglomerates. In liquids, dispersed structures can raise low-shear viscosity and create thixotropy: the material flows under shear and rebuilds at rest. This can help coatings resist settling or sag, depending on concentration, dispersion and chemistry.

Evonik lists rheology and thixotropy control, anti-settling, thickening and anti-sagging among AEROSIL 200 uses. WACKER describes HDK N20 as a thickening and thixotropic agent for organic systems and a free-flow additive in technical powders. Those product descriptions identify possible roles, not guaranteed results in every paint, adhesive, sealant, silicone or powder blend. Test the material in the full formulation and include storage and application conditions. [1][2]

2. Start the trial with the right specification

Confirm hydrophilic or modified hydrophobic surface, BET range, pH conditions, loss on drying and tamped density. Evonik AEROSIL 200 lists 175–225 m²/g BET, pH 3.7–4.5 in 4% dispersion, ≤1.5% loss on drying and about 50 g/L tamped density; WACKER HDK N20 lists 175–225 m²/g, pH 3.8–4.3, <1.5% loss and about 40 g/L. These are brand-specific reference values. [1][2]

Record the baseline: raw-material lots, solids, resin, pigment loading, temperature and mixer. Keep a no-silica control and use the same vessel, blade, fill level and conditions; an unstable control makes comparisons inconclusive.

Example grade data for comparison

Reference parameter

Evonik AEROSIL 200

WACKER HDK N20

BET surface area

175–225 m²/g

175–225 m²/g

pH

3.7–4.5 in 4% dispersion

3.8–4.3

Loss on drying

≤1.5% at 105°C, 2 h

<1.5% at 105°C, 2 h

Tamped density

Approx. 50 g/L

Approx. 40 g/L

Values are for the named reference products only and use the conditions stated by each manufacturer. Do not treat this comparison as Lemeng product data or proof of interchangeability.

3. Add and disperse with a repeatable sequence

Addition rate, wetting and shear affect dispersion. Controlled addition into a suitable circulation zone can reduce floating powder and agglomerates. Addition point depends on chemistry, mixer geometry and viscosity. Follow grade guidance and dust controls; record sequence, time, speed and temperature.

Check for agglomerates and entrained air. Use a grind gauge or microscopy only where suitable. Avoid indefinite mixing, which can add heat or change rheology. Set a repeatable endpoint using fineness, viscosity or another relevant measure.

4. Measure the outcomes that matter

For coatings, measure viscosity at relevant shear conditions, sag, leveling, settling and appearance. For adhesives, check extrusion, bead shape and slump; for powders, define a flow method and control humidity and conditioning. A single viscosity value may not predict application and storage behavior.

Evonik’s coating-specific product information for AEROSIL 200 describes a recommended addition range of 1.0–2.0% as supplied, calculated on the total formulation. That recommendation belongs to the named coating additive product and its guidance; it is not a universal dosage for all fumed silica, resin systems or Lemeng material. Start from the exact grade supplier’s recommendation, test a controlled range, and confirm the final loading through performance and cost evaluation. [3]

If storage conditions vary, compare initial results with aged samples equilibrated to test temperature. State whether remixing is allowed; settling or viscosity drift may appear after manufacture.

5. A simple, defensible batch comparison

Use a control and trial batches with the same base and process. Set addition levels from the candidate supplier’s guidance and formulation limits; do not transfer another brand’s dosage. Record mass basis, mixing, temperature, rest time, viscosity, sag or settling and appearance. Repeat if results vary widely.

Do not maximize viscosity: excess structure can hinder pumping, filling or application and reduce leveling. Balance stability with processability and evaluate cost per unit, including mixing time, scrap, cleaning and downstream effects.

6. Storage, handling and workplace controls

Keep bags sealed in dry conditions and protect them from moisture and volatile contamination. Evonik recommends closed containers under dry conditions and protecting AEROSIL 200 from volatile substances; its product information gives a two-year use period for that grade. Follow the exact supplier label and shelf-life statement for the material you purchase. After opening, reseal promptly and use clean tools to prevent foreign-material contamination. [1]

Fine powder can become airborne during charging, transfer and cleanup. Use closed transfer or local exhaust where practicable, minimize free fall, and avoid dry sweeping or compressed-air cleaning that redistributes dust. Follow the current SDS, workplace exposure assessment and local regulations for ventilation and PPE. NIOSH lists 6 mg/m³ TWA as its recommended exposure limit for amorphous silica in its Pocket Guide; it is a U.S. recommendation for a broad substance category, not a substitute for jurisdiction-specific compliance or a product-specific SDS. [4]

7. Questions to resolve before scale-up

Ask the supplier for a current TDS, SDS and certificate format; confirm lot-to-lot limits, test methods, packaging, storage and shelf-life conditions. Clarify whether a “200” designation is nominal or part of a defined grade name. If the product is used in a regulated application, obtain market-specific declarations for that exact grade and intended use. A generic statement that a material is silica or has a 200 m²/g surface area is not enough to establish food, pharmaceutical or cosmetic suitability.

Before scale-up, verify dispersion at production batch size and check dust, heat, dead zones, filters, pumps and filling. A plant trial can reveal transfer or cleaning issues missed in a beaker.

FAQ

Will Hydrophilic Fumed Silica 200 always prevent settling? No. The effect depends on formulation, dispersion, dosage and storage conditions.

Can I use 1–2% in every system? No. That is an Evonik recommendation for its named coating product, not a universal rule. Follow the exact grade guidance and test.

Why does dispersion quality matter? Agglomerates and uneven distribution can produce inconsistent viscosity, surface appearance and batch repeatability.

Is amorphous fumed silica dust harmless? Do not assume that. Follow the product SDS, exposure assessment, local rules and appropriate dust-control practices.

Conclusion

Using Hydrophilic Fumed Silica 200 effectively is a formulation exercise, not a matter of selecting a number and copying a dosage. Verify the grade and test methods, control the addition sequence, measure rheology and end-use performance, and check storage stability before scale-up. Supplier references provide a sound starting point, while a controlled trial determines whether the exact Lemeng grade works in the customer’s actual formulation.